NMR Restraints Grid |
Result table
image | mrblock_id | pdb_id | cing | stage | position | program | type | subtype | subsubtype |
653164 | 6l8v | cing | 1-original | 1 | XPLOR/CNS | distance | NOE | simple |
# Restraints file 1: inter-noe.tbl assign (segid AN1 and resid 56 and name HG2#) (segid AN2 and resid 95 and name HG2#) 4.0 1.0 1.0 assign (segid AN2 and resid 56 and name HG2#) (segid AN1 and resid 95 and name HG2#) 4.0 1.0 1.0 assign (segid AN1 and resid 60 and name HN) (segid AN2 and resid 95 and name HG1#) 3.5 1.0 1.0 assign (segid AN2 and resid 60 and name HN) (segid AN1 and resid 95 and name HG1#) 3.5 1.0 1.0 assign (segid AN1 and resid 60 and name HN) (segid AN2 and resid 95 and name HG2#) 3.5 1.0 1.0 assign (segid AN2 and resid 60 and name HN) (segid AN1 and resid 95 and name HG2#) 3.5 1.0 1.0 assign (segid AN1 and resid 63 and name HD1#) (segid AN2 and resid 79 and name HE#) 3.5 1.0 1.0 assign (segid AN2 and resid 63 and name HD1#) (segid AN1 and resid 79 and name HE#) 3.5 1.0 1.0 assign (segid AN1 and resid 66 and name HG2#) (segid AN2 and resid 112 and name HB#) 3.5 1.0 1.0 assign (segid AN2 and resid 66 and name HG2#) (segid AN1 and resid 112 and name HB#) 3.5 1.0 1.0 assign (segid AN1 and resid 66 and name HG2#) (segid AN2 and resid 70 and name HD1#) 3.5 1.0 1.0 assign (segid AN2 and resid 66 and name HG2#) (segid AN1 and resid 70 and name HD1#) 3.5 1.0 1.0 assign (segid AN1 and resid 67 and name HN) (segid AN2 and resid 109 and name HD#) 3.5 1.0 1.0 assign (segid AN2 and resid 67 and name HN) (segid AN1 and resid 109 and name HD#) 3.5 1.0 1.0 assign (segid AN1 and resid 67 and name HN) (segid AN2 and resid 112 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN1 and resid 112 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN2 and resid 109 and name HG#) 3.5 1.0 1.0 assign (segid AN2 and resid 68 and name HN) (segid AN1 and resid 109 and name HG#) 3.5 1.0 1.0 assign (segid AN1 and resid 70 and name HD1#) (segid AN2 and resid 66 and name HG2#) 3.5 1.0 1.0 assign (segid AN2 and resid 70 and name HD1#) (segid AN1 and resid 66 and name HG2#) 3.5 1.0 1.0 assign (segid AN1 and resid 76 and name HD2#) (segid AN2 and resid 63 and name HD1#) 3.2 1.0 1.0 assign (segid AN2 and resid 76 and name HD2#) (segid AN1 and resid 63 and name HD1#) 3.2 1.0 1.0 assign (segid AN1 and resid 76 and name HD2#) (segid AN2 and resid 63 and name HD2#) 3.0 1.0 1.0 assign (segid AN2 and resid 76 and name HD2#) (segid AN1 and resid 63 and name HD2#) 3.0 1.0 1.0 assign (segid AN1 and resid 80 and name HN) (segid AN2 and resid 59 and name HD1#) 3.5 1.0 1.0 assign (segid AN2 and resid 80 and name HN) (segid AN1 and resid 59 and name HD1#) 3.5 1.0 1.0 assign (segid AN1 and resid 80 and name HN) (segid AN2 and resid 59 and name HD2#) 3.5 1.0 1.0 assign (segid AN2 and resid 80 and name HN) (segid AN1 and resid 59 and name HD2#) 3.5 1.0 1.0 assign (segid AN1 and resid 80 and name HG2#) (segid AN2 and resid 59 and name HD2#) 3.0 1.0 1.0 assign (segid AN2 and resid 80 and name HG2#) (segid AN1 and resid 59 and name HD2#) 3.0 1.0 1.0 assign (segid AN1 and resid 80 and name HG2#) (segid AN2 and resid 63 and name HD1#) 3.0 1.0 1.0 assign (segid AN2 and resid 80 and name HG2#) (segid AN1 and resid 63 and name HD1#) 3.0 1.0 1.0 assign (segid AN1 and resid 94 and name HN) (segid AN2 and resid 56 and name HG2#) 4.0 1.0 1.0 assign (segid AN2 and resid 94 and name HN) (segid AN1 and resid 56 and name HG2#) 4.0 1.0 1.0 assign (segid AN1 and resid 95 and name HG#) (segid AN2 and resid 60 and name HN) 4.0 1.0 1.0 assign (segid AN2 and resid 95 and name HG#) (segid AN1 and resid 60 and name HN) 4.0 1.0 1.0 assign (segid AN1 and resid 95 and name HN) (segid AN2 and resid 56 and name HG2#) 3.0 1.0 1.0 assign (segid AN2 and resid 95 and name HN) (segid AN1 and resid 56 and name HG2#) 3.0 1.0 1.0 assign (segid AN1 and resid 107 and name HE1) (segid AN2 and resid 119 and name HA) 3.5 1.0 1.0 assign (segid AN2 and resid 107 and name HE1) (segid AN1 and resid 119 and name HA) 3.5 1.0 1.0 assign (segid AN1 and resid 107 and name HE1) (segid AN2 and resid 122 and name HD1#) 3.5 1.0 1.0 assign (segid AN2 and resid 107 and name HE1) (segid AN1 and resid 122 and name HD1#) 3.5 1.0 1.0 assign (segid AN1 and resid 111 and name HN) (segid AN2 and resid 111 and name HG1#) 3.5 1.0 1.0 assign (segid AN2 and resid 111 and name HN) (segid AN1 and resid 111 and name HG1#) 3.5 1.0 1.0 assign (segid AN1 and resid 111 and name HG2#) (segid AN2 and resid 115 and name HB#) 3.0 1.0 1.0 assign (segid AN2 and resid 111 and name HG2#) (segid AN1 and resid 115 and name HB#) 3.0 1.0 1.0 assign (segid AN1 and resid 112 and name HN) (segid AN2 and resid 111 and name HG1#) 3.7 1.0 1.0 assign (segid AN2 and resid 112 and name HN) (segid AN1 and resid 111 and name HG1#) 3.7 1.0 1.0 assign (segid AN1 and resid 112 and name HB#) (segid AN2 and resid 63 and name HD2#) 4.0 1.0 1.0 assign (segid AN2 and resid 112 and name HB#) (segid AN1 and resid 63 and name HD2#) 4.0 1.0 1.0 assign (segid AN1 and resid 112 and name HB#) (segid AN2 and resid 67 and name HA#) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HB#) (segid AN1 and resid 67 and name HA#) 4.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN2 and resid 111 and name HG2#) 4.0 1.0 1.0 assign (segid AN2 and resid 114 and name HN) (segid AN1 and resid 111 and name HG2#) 4.0 1.0 1.0 assign (segid AN1 and resid 115 and name HN) (segid AN2 and resid 111 and name HG2#) 3.0 1.0 1.0 assign (segid AN2 and resid 115 and name HN) (segid AN1 and resid 111 and name HG2#) 3.0 1.0 1.0 assign (segid AN1 and resid 118 and name HN) (segid AN2 and resid 107 and name HE1) 4.0 1.0 1.0 assign (segid AN2 and resid 118 and name HN) (segid AN1 and resid 107 and name HE1) 4.0 1.0 1.0 assign (segid AN1 and resid 122 and name HD2#) (segid AN2 and resid 107 and name HE1) 4.0 1.0 1.0 assign (segid AN2 and resid 122 and name HD2#) (segid AN1 and resid 107 and name HE1) 4.0 1.0 1.0 # Restraints file 2: D_1300013940_mr_P2.xplor-nih.V3 assign (segid AN1 and resid 53 and name HN) (segid AN1 and resid 52 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 53 and name HN) (segid AN2 and resid 52 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 53 and name HN) (segid AN1 and resid 52 and name HE#) 4.0 0.5 0.5 assign (segid AN2 and resid 53 and name HN) (segid AN2 and resid 52 and name HE#) 4.0 0.5 0.5 assign (segid AN1 and resid 53 and name HN) (segid AN1 and resid 54 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 53 and name HN) (segid AN2 and resid 54 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 53 and name HN) (segid AN1 and resid 54 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 53 and name HN) (segid AN2 and resid 54 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 53 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 53 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 53 and name HB#) 4.4 0.5 0.5 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 53 and name HB#) 4.4 0.5 0.5 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 58 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 58 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 52 and name HA) 4.0 1.0 1.0 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 52 and name HA) 4.0 1.0 1.0 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 58 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 58 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 54 and name HN) (segid AN1 and resid 57 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 54 and name HN) (segid AN2 and resid 57 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 54 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 54 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 55 and name HB#) 2.7 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 55 and name HB#) 2.7 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 56 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 56 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 57 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 57 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 54 and name HB#) 3.6 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 54 and name HB#) 3.6 0.5 0.5 assign (segid AN1 and resid 56 and name HN) (segid AN1 and resid 55 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 56 and name HN) (segid AN2 and resid 55 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 56 and name HN) (segid AN1 and resid 55 and name HB#) 3.9 1.0 1.0 assign (segid AN2 and resid 56 and name HN) (segid AN2 and resid 55 and name HB#) 3.9 1.0 1.0 assign (segid AN1 and resid 56 and name HN) (segid AN1 and resid 57 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 56 and name HN) (segid AN2 and resid 57 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 56 and name HN) (segid AN1 and resid 57 and name HB#) 4.5 0.5 0.5 assign (segid AN2 and resid 56 and name HN) (segid AN2 and resid 57 and name HB#) 4.5 0.5 0.5 assign (segid AN1 and resid 56 and name HG2#) (segid AN1 and resid 57 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 56 and name HG2#) (segid AN2 and resid 57 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 57 and name HN) (segid AN1 and resid 56 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 57 and name HN) (segid AN2 and resid 56 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 57 and name HN) (segid AN1 and resid 55 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 57 and name HN) (segid AN2 and resid 55 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 57 and name HN) (segid AN1 and resid 56 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 57 and name HN) (segid AN2 and resid 56 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 57 and name HN) (segid AN1 and resid 56 and name HG#) 4.0 1.0 1.0 assign (segid AN2 and resid 57 and name HN) (segid AN2 and resid 56 and name HG#) 4.0 1.0 1.0 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 56 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 56 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 55 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 55 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 58 and name HB#) 2.6 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 58 and name HB#) 2.6 0.5 0.5 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 59 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 59 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 60 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 60 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 59 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 59 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 59 and name HB#) 2.4 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 59 and name HB#) 2.4 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 58 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 58 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 60 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 60 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 56 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 56 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 58 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 58 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 61 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 61 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 59 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 59 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 59 and name HB#) 2.4 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 59 and name HB#) 2.4 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 61 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 61 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 57 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 57 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 59 and name HG) 4.0 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 59 and name HG) 4.0 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 61 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 61 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 60 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 60 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 62 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 62 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 58 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 58 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 61 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 61 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 58 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 58 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 61 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 63 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 61 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 63 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 59 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 59 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 58 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 58 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 61 and name HB#) 3.5 1.0 1.0 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 61 and name HB#) 3.5 1.0 1.0 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 61 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 61 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 62 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 62 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 60 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 60 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 62 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 62 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 63 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 63 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 63 and name HB#) 2.3 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 63 and name HB#) 2.3 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 63 and name HG) 2.6 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 63 and name HG) 2.6 0.5 0.5 assign (segid AN1 and resid 64 and name HN) (segid AN1 and resid 64 and name HB#) 2.6 0.5 0.5 assign (segid AN2 and resid 64 and name HN) (segid AN2 and resid 64 and name HB#) 2.6 0.5 0.5 assign (segid AN1 and resid 64 and name HN) (segid AN1 and resid 61 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 64 and name HN) (segid AN2 and resid 61 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 65 and name HN) (segid AN1 and resid 66 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 65 and name HN) (segid AN2 and resid 66 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 65 and name HN) (segid AN1 and resid 62 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 65 and name HN) (segid AN2 and resid 62 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 65 and name HN) (segid AN1 and resid 65 and name HB#) 2.6 0.5 0.5 assign (segid AN2 and resid 65 and name HN) (segid AN2 and resid 65 and name HB#) 2.6 0.5 0.5 assign (segid AN1 and resid 66 and name HN) (segid AN1 and resid 63 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 66 and name HN) (segid AN2 and resid 63 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 66 and name HN) (segid AN1 and resid 66 and name HB) 2.2 0.5 0.5 assign (segid AN2 and resid 66 and name HN) (segid AN2 and resid 66 and name HB) 2.2 0.5 0.5 assign (segid AN1 and resid 67 and name HN) (segid AN1 and resid 66 and name HG2#) 3.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN2 and resid 66 and name HG2#) 3.0 0.5 0.5 assign (segid AN1 and resid 67 and name HN) (segid AN1 and resid 66 and name HB) 3.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN2 and resid 66 and name HB) 3.0 0.5 0.5 assign (segid AN1 and resid 67 and name HN) (segid AN1 and resid 66 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN2 and resid 66 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 67 and name HN) (segid AN1 and resid 68 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN2 and resid 68 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 69 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 69 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 67 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 67 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 70 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 70 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 65 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 65 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 68 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 68 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 67 and name HA#) 3.0 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 67 and name HA#) 3.0 0.5 0.5 assign (segid AN1 and resid 69 and name HN) (segid AN1 and resid 70 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 69 and name HN) (segid AN2 and resid 70 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 69 and name HN) (segid AN1 and resid 66 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 69 and name HN) (segid AN2 and resid 66 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 70 and name HN) (segid AN1 and resid 69 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 70 and name HN) (segid AN2 and resid 69 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 70 and name HN) (segid AN1 and resid 71 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 70 and name HN) (segid AN2 and resid 71 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 70 and name HD1#) (segid AN1 and resid 76 and name HD1#) 3.0 0.5 0.5 assign (segid AN1 and resid 70 and name HD1#) (segid AN1 and resid 115 and name HD#) 3.5 0.5 0.5 assign (segid AN1 and resid 70 and name HD2#) (segid AN1 and resid 115 and name HE#) 3.5 0.5 0.5 assign (segid AN2 and resid 70 and name HD1#) (segid AN2 and resid 76 and name HD1#) 3.0 0.5 0.5 assign (segid AN2 and resid 70 and name HD1#) (segid AN2 and resid 115 and name HD#) 3.5 0.5 0.5 assign (segid AN2 and resid 70 and name HD2#) (segid AN2 and resid 115 and name HE#) 3.5 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 68 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 68 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 70 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 70 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 70 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 70 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 70 and name HG) 4.0 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 70 and name HG) 4.0 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 70 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 70 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 72 and name HN) (segid AN1 and resid 71 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 72 and name HN) (segid AN1 and resid 73 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 72 and name HN) (segid AN1 and resid 73 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 72 and name HN) (segid AN2 and resid 71 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 72 and name HN) (segid AN2 and resid 73 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 72 and name HN) (segid AN2 and resid 73 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 73 and name HN) (segid AN1 and resid 72 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 73 and name HN) (segid AN1 and resid 72 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 73 and name HN) (segid AN1 and resid 74 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 73 and name HN) (segid AN2 and resid 72 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 73 and name HN) (segid AN2 and resid 72 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 73 and name HN) (segid AN2 and resid 74 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 74 and name HN) (segid AN1 and resid 73 and name HA) 2.0 0.5 0.5 assign (segid AN1 and resid 74 and name HN) (segid AN1 and resid 74 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 74 and name HN) (segid AN2 and resid 73 and name HA) 2.0 0.5 0.5 assign (segid AN2 and resid 74 and name HN) (segid AN2 and resid 74 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 75 and name HN) (segid AN1 and resid 74 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 75 and name HN) (segid AN2 and resid 74 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 75 and name HN) (segid AN1 and resid 73 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 75 and name HN) (segid AN1 and resid 76 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 75 and name HN) (segid AN2 and resid 73 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 75 and name HN) (segid AN2 and resid 76 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 76 and name HN) (segid AN1 and resid 75 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 76 and name HN) (segid AN1 and resid 75 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 76 and name HN) (segid AN1 and resid 77 and name HN) 2.6 0.5 0.5 assign (segid AN2 and resid 76 and name HN) (segid AN2 and resid 75 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 76 and name HN) (segid AN2 and resid 75 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 76 and name HN) (segid AN2 and resid 77 and name HN) 2.6 0.5 0.5 assign (segid AN1 and resid 77 and name HN) (segid AN1 and resid 76 and name HD2#) 4.0 0.5 0.5 assign (segid AN1 and resid 77 and name HN) (segid AN1 and resid 76 and name HG) 4.0 0.5 0.5 assign (segid AN1 and resid 77 and name HN) (segid AN1 and resid 78 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 77 and name HN) (segid AN2 and resid 76 and name HD2#) 4.0 0.5 0.5 assign (segid AN2 and resid 77 and name HN) (segid AN2 and resid 76 and name HG) 4.0 0.5 0.5 assign (segid AN2 and resid 77 and name HN) (segid AN2 and resid 78 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 78 and name HN) (segid AN1 and resid 79 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 78 and name HN) (segid AN2 and resid 79 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 78 and name HN) (segid AN1 and resid 77 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 78 and name HN) (segid AN2 and resid 77 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 80 and name HN) (segid AN1 and resid 81 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 80 and name HN) (segid AN2 and resid 81 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 80 and name HD1#) (segid AN1 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN2 and resid 80 and name HD1#) (segid AN2 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN1 and resid 81 and name HN) (segid AN1 and resid 80 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 81 and name HN) (segid AN1 and resid 80 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 81 and name HN) (segid AN1 and resid 82 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 81 and name HN) (segid AN1 and resid 83 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 81 and name HN) (segid AN2 and resid 80 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 81 and name HN) (segid AN2 and resid 80 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 81 and name HN) (segid AN2 and resid 82 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 81 and name HN) (segid AN2 and resid 83 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 81 and name HB#) (segid AN1 and resid 80 and name HB) 4.0 0.5 0.5 assign (segid AN2 and resid 81 and name HB#) (segid AN2 and resid 80 and name HB) 4.0 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 83 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 83 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 81 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 81 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 81 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 81 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 83 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 83 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 80 and name HB) 4.5 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 80 and name HB) 4.5 0.5 0.5 assign (segid AN1 and resid 82 and name HB#) (segid AN1 and resid 79 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 82 and name HB#) (segid AN2 and resid 79 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 82 and name HB#) (segid AN1 and resid 83 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 82 and name HB#) (segid AN2 and resid 83 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HN) (segid AN1 and resid 82 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 83 and name HN) (segid AN2 and resid 82 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 83 and name HN) (segid AN1 and resid 82 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 83 and name HN) (segid AN2 and resid 82 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 83 and name HN) (segid AN1 and resid 84 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 83 and name HN) (segid AN2 and resid 84 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 83 and name HN) (segid AN1 and resid 82 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 83 and name HN) (segid AN2 and resid 82 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG1#) (segid AN1 and resid 120 and name HD1#) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG1#) (segid AN1 and resid 120 and name HD2#) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG2#) (segid AN1 and resid 120 and name HD1#) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG2#) (segid AN1 and resid 120 and name HD2#) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG1#) (segid AN1 and resid 82 and name HB#) 4.5 1.0 1.0 assign (segid AN2 and resid 83 and name HG1#) (segid AN2 and resid 82 and name HB#) 4.5 1.0 1.0 assign (segid AN1 and resid 83 and name HG2#) (segid AN1 and resid 82 and name HB#) 4.5 1.0 1.0 assign (segid AN2 and resid 83 and name HG2#) (segid AN2 and resid 82 and name HB#) 4.5 1.0 1.0 assign (segid AN1 and resid 83 and name HG#) (segid AN1 and resid 84 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 83 and name HG#) (segid AN2 and resid 84 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 83 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 83 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 83 and name HG1#) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 83 and name HG1#) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 83 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 83 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 82 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 82 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 83 and name HB) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 83 and name HB) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 85 and name HA) 4.5 1.0 1.0 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 85 and name HA) 4.5 1.0 1.0 assign (segid AN1 and resid 85 and name HN) (segid AN1 and resid 84 and name HB#) 2.5 0.5 0.5 assign (segid AN2 and resid 85 and name HN) (segid AN2 and resid 84 and name HB#) 2.5 0.5 0.5 assign (segid AN1 and resid 85 and name HN) (segid AN1 and resid 86 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 85 and name HN) (segid AN2 and resid 86 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 85 and name HN) (segid AN1 and resid 86 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 85 and name HN) (segid AN2 and resid 86 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 85 and name HN) (segid AN1 and resid 85 and name HG2#) 2.0 0.5 0.5 assign (segid AN2 and resid 85 and name HN) (segid AN2 and resid 85 and name HG2#) 2.0 0.5 0.5 assign (segid AN1 and resid 85 and name HG2#) (segid AN1 and resid 86 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 85 and name HG2#) (segid AN2 and resid 86 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 86 and name HN) (segid AN1 and resid 85 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 86 and name HN) (segid AN2 and resid 85 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 86 and name HN) (segid AN1 and resid 85 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 86 and name HN) (segid AN2 and resid 85 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 86 and name HN) (segid AN1 and resid 85 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 86 and name HN) (segid AN2 and resid 85 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 87 and name HN) (segid AN1 and resid 86 and name HB#) 3.5 0.5 0.5 assign (segid AN2 and resid 87 and name HN) (segid AN2 and resid 86 and name HB#) 3.5 0.5 0.5 assign (segid AN1 and resid 87 and name HN) (segid AN1 and resid 86 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 87 and name HN) (segid AN2 and resid 86 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 89 and name HN) (segid AN1 and resid 90 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 89 and name HN) (segid AN2 and resid 90 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 89 and name HN) (segid AN1 and resid 87 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 89 and name HN) (segid AN2 and resid 87 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 89 and name HN) (segid AN1 and resid 89 and name HG#) 2.2 0.5 0.5 assign (segid AN2 and resid 89 and name HN) (segid AN2 and resid 89 and name HG#) 2.2 0.5 0.5 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 89 and name HB#) 3.5 0.5 0.5 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 89 and name HB#) 3.5 0.5 0.5 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 89 and name HD#) 4.0 1.0 1.0 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 89 and name HD#) 4.0 1.0 1.0 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 89 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 89 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 91 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 91 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 90 and name HB#) 2.8 0.5 0.5 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 90 and name HB#) 2.8 0.5 0.5 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 120 and name HD2#) 4.0 0.5 0.5 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 120 and name HD2#) 4.0 0.5 0.5 assign (segid AN1 and resid 91 and name HG1#) (segid AN1 and resid 83 and name HG2#) 3.5 1.0 1.0 assign (segid AN2 and resid 91 and name HG1#) (segid AN2 and resid 83 and name HG2#) 3.5 1.0 1.0 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 83 and name HG2#) 3.0 0.5 0.5 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 83 and name HG2#) 3.0 0.5 0.5 assign (segid AN1 and resid 91 and name HG1#) (segid AN1 and resid 83 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 91 and name HG1#) (segid AN2 and resid 83 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 83 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 83 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 91 and name HG1#) (segid AN1 and resid 92 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 91 and name HG1#) (segid AN2 and resid 92 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 92 and name HN) 3.5 1.0 1.0 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 92 and name HN) 3.5 1.0 1.0 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 92 and name HD1) 4.0 1.5 1.5 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 92 and name HD1) 4.0 1.5 1.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 93 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 93 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 91 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 91 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 91 and name HG#) 3.0 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 91 and name HG#) 3.0 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 91 and name HB) 3.5 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 91 and name HB) 3.5 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 93 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 93 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 91 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 91 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 120 and name HD2#) 4.5 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 120 and name HD2#) 4.5 0.5 0.5 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 92 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 92 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 89 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 89 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 90 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 90 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 92 and name HB#) 3.5 1.0 1.0 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 92 and name HB#) 3.5 1.0 1.0 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 94 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 94 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 95 and name HN) 2.8 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 95 and name HN) 2.8 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 93 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 93 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 95 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 95 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 91 and name HA) 3.3 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 91 and name HA) 3.3 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 96 and name HB#) 4.5 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 96 and name HB#) 4.5 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 93 and name HB#) 3.3 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 93 and name HB#) 3.3 0.5 0.5 assign (segid AN1 and resid 95 and name HN) (segid AN1 and resid 94 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 95 and name HN) (segid AN2 and resid 94 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 95 and name HN) (segid AN1 and resid 94 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 95 and name HN) (segid AN2 and resid 94 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 95 and name HN) (segid AN1 and resid 92 and name HA) 3.7 0.5 0.5 assign (segid AN2 and resid 95 and name HN) (segid AN2 and resid 92 and name HA) 3.7 0.5 0.5 assign (segid AN1 and resid 95 and name HN) (segid AN1 and resid 96 and name HB#) 5.0 0.5 0.5 assign (segid AN2 and resid 95 and name HN) (segid AN2 and resid 96 and name HB#) 5.0 0.5 0.5 assign (segid AN1 and resid 95 and name HG2#) (segid AN1 and resid 92 and name HE2) 4.0 1.0 1.0 assign (segid AN2 and resid 95 and name HG2#) (segid AN2 and resid 92 and name HE2) 4.0 1.0 1.0 assign (segid AN1 and resid 95 and name HG2#) (segid AN1 and resid 96 and name HB#) 4.0 1.0 1.0 assign (segid AN2 and resid 95 and name HG2#) (segid AN2 and resid 96 and name HB#) 4.0 1.0 1.0 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 95 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 95 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 97 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 97 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 98 and name HN) 4.5 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 98 and name HN) 4.5 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 93 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 93 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 95 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 95 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 95 and name HG1#) 3.5 1.0 1.0 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 95 and name HG1#) 3.5 1.0 1.0 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 95 and name HG2#) 2.5 1.0 1.0 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 95 and name HG2#) 2.5 1.0 1.0 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 113 and name HD#) 3.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 113 and name HD#) 3.0 0.5 0.5 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 97 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 97 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 97 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 97 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 95 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 95 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 98 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 98 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 96 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 96 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 96 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 96 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 94 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 94 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 93 and name HA) 3.3 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 93 and name HA) 3.3 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 96 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 96 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 98 and name HB#) 4.5 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 98 and name HB#) 4.5 0.5 0.5 assign (segid AN1 and resid 97 and name HB#) (segid AN1 and resid 98 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 97 and name HB#) (segid AN2 and resid 98 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 100 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 100 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 99 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 99 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 97 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 97 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 95 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 95 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 96 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 96 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 97 and name HB#) 2.5 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 97 and name HB#) 2.5 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 98 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 98 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 100 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 100 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 98 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 98 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 96 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 96 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 100 and name HN) (segid AN1 and resid 101 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 100 and name HN) (segid AN2 and resid 101 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 100 and name HN) (segid AN1 and resid 99 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 100 and name HN) (segid AN2 and resid 99 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 100 and name HN) (segid AN1 and resid 97 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 100 and name HN) (segid AN2 and resid 97 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 100 and name HN) (segid AN1 and resid 100 and name HB#) 2.2 1.0 1.0 assign (segid AN2 and resid 100 and name HN) (segid AN2 and resid 100 and name HB#) 2.2 1.0 1.0 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 102 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 102 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 99 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 99 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 100 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 100 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 97 and name HB#) 4.5 1.0 1.0 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 97 and name HB#) 4.5 1.0 1.0 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 100 and name HB#) 3.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 100 and name HB#) 3.5 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 100 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 100 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 98 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 98 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 101 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 101 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 100 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 100 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 99 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 99 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 100 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 100 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 101 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 101 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 101 and name HB#) 3.4 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 101 and name HB#) 3.4 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 102 and name HB#) 2.5 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 102 and name HB#) 2.5 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 104 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 104 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 102 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 102 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 101 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 101 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 102 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 102 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 102 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 102 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 105 and name HN) (segid AN1 and resid 106 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 105 and name HN) (segid AN2 and resid 106 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 106 and name HN) (segid AN1 and resid 105 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 106 and name HN) (segid AN2 and resid 105 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 109 and name HN) (segid AN1 and resid 110 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 109 and name HN) (segid AN2 and resid 110 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 110 and name HN) (segid AN1 and resid 111 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 110 and name HN) (segid AN2 and resid 111 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 110 and name HG1#) (segid AN1 and resid 107 and name HZ#) 3.5 0.5 0.5 assign (segid AN2 and resid 110 and name HG1#) (segid AN2 and resid 107 and name HZ#) 3.5 0.5 0.5 assign (segid AN1 and resid 110 and name HG2#) (segid AN1 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 110 and name HG2#) (segid AN2 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 110 and name HG2#) (segid AN1 and resid 105 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 110 and name HG2#) (segid AN2 and resid 105 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 110 and name HG1#) (segid AN1 and resid 105 and name HE#) 3.5 0.5 0.5 assign (segid AN2 and resid 110 and name HG1#) (segid AN2 and resid 105 and name HE#) 3.5 0.5 0.5 assign (segid AN1 and resid 111 and name HN) (segid AN1 and resid 111 and name HG1#) 4.0 0.5 0.5 assign (segid AN2 and resid 111 and name HN) (segid AN2 and resid 111 and name HG1#) 4.0 0.5 0.5 assign (segid AN1 and resid 111 and name HN) (segid AN1 and resid 111 and name HG2#) 2.5 0.5 0.5 assign (segid AN2 and resid 111 and name HN) (segid AN2 and resid 111 and name HG2#) 2.5 0.5 0.5 assign (segid AN1 and resid 111 and name HN) (segid AN1 and resid 110 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 111 and name HN) (segid AN2 and resid 110 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 111 and name HG1#) 4.0 1.0 1.0 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 111 and name HG1#) 4.0 1.0 1.0 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 111 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 111 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 110 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 110 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 110 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 110 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 114 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 114 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HB#) (segid AN1 and resid 115 and name HE#) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HB#) (segid AN2 and resid 115 and name HE#) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HB#) (segid AN1 and resid 115 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HB#) (segid AN2 and resid 115 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 113 and name HN) (segid AN1 and resid 114 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 113 and name HN) (segid AN2 and resid 114 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 113 and name HN) (segid AN1 and resid 112 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 113 and name HN) (segid AN2 and resid 112 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 113 and name HN) (segid AN1 and resid 112 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 113 and name HN) (segid AN2 and resid 112 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 113 and name HD1#) (segid AN1 and resid 95 and name HG2#) 4.0 1.0 1.0 assign (segid AN1 and resid 113 and name HD#) (segid AN1 and resid 99 and name HE#) 3.5 0.5 0.5 assign (segid AN1 and resid 113 and name HD2#) (segid AN1 and resid 96 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 113 and name HD2#) (segid AN1 and resid 96 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 113 and name HD1#) (segid AN2 and resid 95 and name HG2#) 4.0 1.0 1.0 assign (segid AN2 and resid 113 and name HD#) (segid AN2 and resid 99 and name HE#) 3.5 0.5 0.5 assign (segid AN2 and resid 113 and name HD2#) (segid AN2 and resid 96 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 113 and name HD2#) (segid AN2 and resid 96 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HG) 3.5 1.0 1.0 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HG) 3.5 1.0 1.0 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 115 and name HN) (segid AN1 and resid 116 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 115 and name HN) (segid AN2 and resid 116 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 115 and name HN) (segid AN1 and resid 114 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 115 and name HN) (segid AN2 and resid 114 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 116 and name HN) (segid AN1 and resid 115 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 116 and name HN) (segid AN2 and resid 115 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 118 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 118 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 114 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 114 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 116 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 116 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 117 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 117 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 115 and name HA) 4.5 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 115 and name HA) 4.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 117 and name HB#) (segid AN1 and resid 121 and name HG#) 4.0 1.0 1.0 assign (segid AN2 and resid 117 and name HB#) (segid AN2 and resid 121 and name HG#) 4.0 1.0 1.0 assign (segid AN1 and resid 117 and name HB#) (segid AN1 and resid 120 and name HD#) 4.0 1.0 1.0 assign (segid AN2 and resid 117 and name HB#) (segid AN2 and resid 120 and name HD#) 4.0 1.0 1.0 assign (segid AN1 and resid 117 and name HB#) (segid AN1 and resid 114 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 117 and name HB#) (segid AN2 and resid 114 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 117 and name HB#) (segid AN1 and resid 114 and name HD#) 3.0 0.5 0.5 assign (segid AN2 and resid 117 and name HB#) (segid AN2 and resid 114 and name HD#) 3.0 0.5 0.5 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 121 and name HG#) 4.5 0.5 0.5 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 121 and name HG#) 4.5 0.5 0.5 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 113 and name HA) 4.5 1.0 1.0 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 113 and name HA) 4.5 1.0 1.0 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 119 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 119 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 117 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 117 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 118 and name HB#) 2.5 0.5 0.5 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 118 and name HB#) 2.5 0.5 0.5 assign (segid AN1 and resid 119 and name HN) (segid AN1 and resid 121 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 119 and name HN) (segid AN2 and resid 121 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 119 and name HN) (segid AN1 and resid 118 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 119 and name HN) (segid AN2 and resid 118 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 119 and name HN) (segid AN1 and resid 120 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 119 and name HN) (segid AN2 and resid 120 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 117 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 117 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 119 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 119 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 120 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 120 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 121 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 121 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 119 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 119 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HD1#) (segid AN1 and resid 83 and name HG2#) 3.5 0.5 0.5 assign (segid AN2 and resid 120 and name HD1#) (segid AN2 and resid 83 and name HG2#) 3.5 0.5 0.5 assign (segid AN1 and resid 120 and name HD2#) (segid AN1 and resid 83 and name HG2#) 3.5 0.5 0.5 assign (segid AN2 and resid 120 and name HD2#) (segid AN2 and resid 83 and name HG2#) 3.5 0.5 0.5 assign (segid AN1 and resid 120 and name HD1#) (segid AN1 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HD1#) (segid AN2 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HD2#) (segid AN1 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HD2#) (segid AN2 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HD2#) (segid AN1 and resid 92 and name HD#) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HD2#) (segid AN2 and resid 92 and name HD#) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HD2#) (segid AN1 and resid 92 and name HE#) 4.0 0.5 0.5 assign (segid AN2 and resid 120 and name HD2#) (segid AN2 and resid 92 and name HE#) 4.0 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 120 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 120 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 121 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 121 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 122 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 122 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 120 and name HG) 3.5 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 120 and name HG) 3.5 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 120 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 120 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 121 and name HG1#) (segid AN1 and resid 117 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 121 and name HG1#) (segid AN2 and resid 117 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 121 and name HG1#) (segid AN1 and resid 117 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 121 and name HG1#) (segid AN2 and resid 117 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 121 and name HG2#) (segid AN1 and resid 117 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 121 and name HG2#) (segid AN2 and resid 117 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 121 and name HG2#) (segid AN1 and resid 122 and name HG) 3.5 1.0 1.0 assign (segid AN2 and resid 121 and name HG2#) (segid AN2 and resid 122 and name HG) 3.5 1.0 1.0 assign (segid AN1 and resid 121 and name HG#) (segid AN1 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 121 and name HG#) (segid AN2 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 121 and name HG#) (segid AN1 and resid 118 and name HA) 3.5 1.0 1.0 assign (segid AN2 and resid 121 and name HG#) (segid AN2 and resid 118 and name HA) 3.5 1.0 1.0 assign (segid AN1 and resid 121 and name HG#) (segid AN1 and resid 122 and name HN) 3.5 1.0 1.0 assign (segid AN2 and resid 121 and name HG#) (segid AN2 and resid 122 and name HN) 3.5 1.0 1.0 assign (segid AN1 and resid 122 and name HN) (segid AN1 and resid 121 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 122 and name HN) (segid AN2 and resid 121 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 122 and name HN) (segid AN1 and resid 121 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 122 and name HN) (segid AN2 and resid 121 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 122 and name HN) (segid AN1 and resid 122 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 122 and name HN) (segid AN2 and resid 122 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 122 and name HD1#) (segid AN1 and resid 118 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 122 and name HD1#) (segid AN2 and resid 118 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 122 and name HD#) (segid AN1 and resid 119 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 122 and name HD#) (segid AN2 and resid 119 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 122 and name HD#) (segid AN1 and resid 122 and name HB#) 2.1 0.5 0.5 assign (segid AN2 and resid 122 and name HD#) (segid AN2 and resid 122 and name HB#) 2.1 0.5 0.5 assign (segid AN1 and resid 123 and name HN) (segid AN1 and resid 120 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 123 and name HN) (segid AN2 and resid 120 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 123 and name HN) (segid AN1 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 123 and name HN) (segid AN2 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 123 and name HN) (segid AN1 and resid 123 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 123 and name HN) (segid AN2 and resid 123 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 123 and name HN) (segid AN1 and resid 124 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 123 and name HN) (segid AN2 and resid 124 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 123 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 123 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 120 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 120 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 121 and name HA) 3.3 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 121 and name HA) 3.3 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 123 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 123 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 123 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 123 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 124 and name HB#) (segid AN1 and resid 123 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 124 and name HB#) (segid AN2 and resid 123 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 124 and name HB#) (segid AN1 and resid 121 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 124 and name HB#) (segid AN2 and resid 121 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 125 and name HN) (segid AN1 and resid 126 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 125 and name HN) (segid AN2 and resid 126 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 125 and name HN) (segid AN1 and resid 124 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 125 and name HN) (segid AN2 and resid 124 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 125 and name HN) (segid AN1 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 125 and name HN) (segid AN2 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 125 and name HN) (segid AN1 and resid 126 and name HA) 4.0 1.0 1.0 assign (segid AN2 and resid 125 and name HN) (segid AN2 and resid 126 and name HA) 4.0 1.0 1.0 assign (segid AN1 and resid 125 and name HD2#) (segid AN1 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 125 and name HD2#) (segid AN2 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 125 and name HD1#) (segid AN1 and resid 122 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 125 and name HD1#) (segid AN2 and resid 122 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 127 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 127 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 125 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 125 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 125 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 125 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 123 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 123 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 125 and name HG) 3.5 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 125 and name HG) 3.5 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 125 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 125 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 124 and name HB#) 5.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 124 and name HB#) 5.0 0.5 0.5 assign (segid AN1 and resid 127 and name HN) (segid AN1 and resid 126 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 127 and name HN) (segid AN2 and resid 126 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 127 and name HN) (segid AN1 and resid 128 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 127 and name HN) (segid AN2 and resid 128 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 127 and name HN) (segid AN1 and resid 126 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 127 and name HN) (segid AN2 and resid 126 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 127 and name HN) (segid AN1 and resid 125 and name HD1#) 4.5 1.0 1.0 assign (segid AN2 and resid 127 and name HN) (segid AN2 and resid 125 and name HD1#) 4.5 1.0 1.0 assign (segid AN1 and resid 127 and name HG2#) (segid AN1 and resid 128 and name HN) 3.0 1.0 1.0 assign (segid AN2 and resid 127 and name HG2#) (segid AN2 and resid 128 and name HN) 3.0 1.0 1.0 assign (segid AN1 and resid 128 and name HN) (segid AN1 and resid 127 and name HB) 4.0 0.5 0.5 assign (segid AN2 and resid 128 and name HN) (segid AN2 and resid 127 and name HB) 4.0 0.5 0.5 assign (segid AN1 and resid 129 and name HN) (segid AN1 and resid 128 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 129 and name HN) (segid AN2 and resid 128 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 129 and name HN) (segid AN1 and resid 128 and name HD#) 3.5 0.5 0.5 assign (segid AN2 and resid 129 and name HN) (segid AN2 and resid 128 and name HD#) 3.5 0.5 0.5 assign (segid AN1 and resid 129 and name HN) (segid AN1 and resid 128 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 129 and name HN) (segid AN2 and resid 128 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 129 and name HN) (segid AN1 and resid 128 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 129 and name HN) (segid AN2 and resid 128 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 129 and name HN) (segid AN1 and resid 130 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 129 and name HN) (segid AN2 and resid 130 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 130 and name HN) (segid AN1 and resid 129 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 130 and name HN) (segid AN2 and resid 129 and name HN) 4.0 0.5 0.5 # Restraints file 3: D_1300013940_mr_P1.xplor-nih.V3 assign (segid AN1 and resid 53 and name HN) (segid AN1 and resid 52 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 53 and name HN) (segid AN2 and resid 52 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 53 and name HN) (segid AN1 and resid 52 and name HE#) 4.0 0.5 0.5 assign (segid AN2 and resid 53 and name HN) (segid AN2 and resid 52 and name HE#) 4.0 0.5 0.5 assign (segid AN1 and resid 53 and name HN) (segid AN1 and resid 54 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 53 and name HN) (segid AN2 and resid 54 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 53 and name HN) (segid AN1 and resid 54 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 53 and name HN) (segid AN2 and resid 54 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 53 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 53 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 53 and name HB#) 4.4 0.5 0.5 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 53 and name HB#) 4.4 0.5 0.5 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 58 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 58 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 52 and name HA) 4.0 1.0 1.0 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 52 and name HA) 4.0 1.0 1.0 assign (segid AN1 and resid 54 and name HB#) (segid AN1 and resid 58 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 54 and name HB#) (segid AN2 and resid 58 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 54 and name HN) (segid AN1 and resid 57 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 54 and name HN) (segid AN2 and resid 57 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 54 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 54 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 55 and name HB#) 2.7 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 55 and name HB#) 2.7 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 56 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 56 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 57 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 57 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 55 and name HN) (segid AN1 and resid 54 and name HB#) 3.6 0.5 0.5 assign (segid AN2 and resid 55 and name HN) (segid AN2 and resid 54 and name HB#) 3.6 0.5 0.5 assign (segid AN1 and resid 56 and name HN) (segid AN1 and resid 55 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 56 and name HN) (segid AN2 and resid 55 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 56 and name HN) (segid AN1 and resid 55 and name HB#) 3.9 1.0 1.0 assign (segid AN2 and resid 56 and name HN) (segid AN2 and resid 55 and name HB#) 3.9 1.0 1.0 assign (segid AN1 and resid 56 and name HN) (segid AN1 and resid 57 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 56 and name HN) (segid AN2 and resid 57 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 56 and name HN) (segid AN1 and resid 57 and name HB#) 4.5 0.5 0.5 assign (segid AN2 and resid 56 and name HN) (segid AN2 and resid 57 and name HB#) 4.5 0.5 0.5 assign (segid AN1 and resid 56 and name HG2#) (segid AN1 and resid 57 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 56 and name HG2#) (segid AN2 and resid 57 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 57 and name HN) (segid AN1 and resid 56 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 57 and name HN) (segid AN2 and resid 56 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 57 and name HN) (segid AN1 and resid 55 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 57 and name HN) (segid AN2 and resid 55 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 57 and name HN) (segid AN1 and resid 56 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 57 and name HN) (segid AN2 and resid 56 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 57 and name HN) (segid AN1 and resid 56 and name HG#) 4.0 1.0 1.0 assign (segid AN2 and resid 57 and name HN) (segid AN2 and resid 56 and name HG#) 4.0 1.0 1.0 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 56 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 56 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 55 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 55 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 58 and name HB#) 2.6 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 58 and name HB#) 2.6 0.5 0.5 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 59 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 59 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 58 and name HN) (segid AN1 and resid 60 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 58 and name HN) (segid AN2 and resid 60 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 59 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 59 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 59 and name HB#) 2.4 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 59 and name HB#) 2.4 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 58 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 58 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 60 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 60 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 56 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 56 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 58 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 58 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 59 and name HN) (segid AN1 and resid 61 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 59 and name HN) (segid AN2 and resid 61 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 59 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 59 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 59 and name HB#) 2.4 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 59 and name HB#) 2.4 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 61 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 61 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 57 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 57 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 59 and name HG) 4.0 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 59 and name HG) 4.0 0.5 0.5 assign (segid AN1 and resid 60 and name HN) (segid AN1 and resid 61 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 60 and name HN) (segid AN2 and resid 61 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 60 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 60 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 62 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 62 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 58 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 58 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 61 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 61 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 61 and name HN) (segid AN1 and resid 58 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 61 and name HN) (segid AN2 and resid 58 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 61 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 63 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 61 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 63 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 59 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 59 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 58 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 58 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 61 and name HB#) 3.5 1.0 1.0 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 61 and name HB#) 3.5 1.0 1.0 assign (segid AN1 and resid 62 and name HN) (segid AN1 and resid 61 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 62 and name HN) (segid AN2 and resid 61 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 62 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 62 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 60 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 60 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 62 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 62 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 63 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 63 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 63 and name HB#) 2.3 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 63 and name HB#) 2.3 0.5 0.5 assign (segid AN1 and resid 63 and name HN) (segid AN1 and resid 63 and name HG) 2.6 0.5 0.5 assign (segid AN2 and resid 63 and name HN) (segid AN2 and resid 63 and name HG) 2.6 0.5 0.5 assign (segid AN1 and resid 64 and name HN) (segid AN1 and resid 64 and name HB#) 2.6 0.5 0.5 assign (segid AN2 and resid 64 and name HN) (segid AN2 and resid 64 and name HB#) 2.6 0.5 0.5 assign (segid AN1 and resid 64 and name HN) (segid AN1 and resid 61 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 64 and name HN) (segid AN2 and resid 61 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 65 and name HN) (segid AN1 and resid 66 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 65 and name HN) (segid AN2 and resid 66 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 65 and name HN) (segid AN1 and resid 62 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 65 and name HN) (segid AN2 and resid 62 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 65 and name HN) (segid AN1 and resid 65 and name HB#) 2.6 0.5 0.5 assign (segid AN2 and resid 65 and name HN) (segid AN2 and resid 65 and name HB#) 2.6 0.5 0.5 assign (segid AN1 and resid 66 and name HN) (segid AN1 and resid 63 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 66 and name HN) (segid AN2 and resid 63 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 66 and name HN) (segid AN1 and resid 66 and name HB) 2.2 0.5 0.5 assign (segid AN2 and resid 66 and name HN) (segid AN2 and resid 66 and name HB) 2.2 0.5 0.5 assign (segid AN1 and resid 67 and name HN) (segid AN1 and resid 66 and name HG2#) 3.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN2 and resid 66 and name HG2#) 3.0 0.5 0.5 assign (segid AN1 and resid 67 and name HN) (segid AN1 and resid 66 and name HB) 3.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN2 and resid 66 and name HB) 3.0 0.5 0.5 assign (segid AN1 and resid 67 and name HN) (segid AN1 and resid 66 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN2 and resid 66 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 67 and name HN) (segid AN1 and resid 68 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 67 and name HN) (segid AN2 and resid 68 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 69 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 69 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 67 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 67 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 70 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 70 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 65 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 65 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 68 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 68 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 68 and name HN) (segid AN1 and resid 67 and name HA#) 3.0 0.5 0.5 assign (segid AN2 and resid 68 and name HN) (segid AN2 and resid 67 and name HA#) 3.0 0.5 0.5 assign (segid AN1 and resid 69 and name HN) (segid AN1 and resid 70 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 69 and name HN) (segid AN2 and resid 70 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 69 and name HN) (segid AN1 and resid 66 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 69 and name HN) (segid AN2 and resid 66 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 70 and name HN) (segid AN1 and resid 69 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 70 and name HN) (segid AN2 and resid 69 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 70 and name HN) (segid AN1 and resid 71 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 70 and name HN) (segid AN2 and resid 71 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 70 and name HD1#) (segid AN1 and resid 76 and name HD1#) 3.0 0.5 0.5 assign (segid AN1 and resid 70 and name HD1#) (segid AN1 and resid 115 and name HD#) 3.5 0.5 0.5 assign (segid AN1 and resid 70 and name HD2#) (segid AN1 and resid 115 and name HE#) 3.5 0.5 0.5 assign (segid AN2 and resid 70 and name HD1#) (segid AN2 and resid 76 and name HD1#) 3.0 0.5 0.5 assign (segid AN2 and resid 70 and name HD1#) (segid AN2 and resid 115 and name HD#) 3.5 0.5 0.5 assign (segid AN2 and resid 70 and name HD2#) (segid AN2 and resid 115 and name HE#) 3.5 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 68 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 68 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 70 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 70 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 70 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 70 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 70 and name HG) 4.0 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 70 and name HG) 4.0 0.5 0.5 assign (segid AN1 and resid 71 and name HN) (segid AN1 and resid 70 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 71 and name HN) (segid AN2 and resid 70 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 72 and name HN) (segid AN1 and resid 71 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 72 and name HN) (segid AN1 and resid 73 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 72 and name HN) (segid AN1 and resid 73 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 72 and name HN) (segid AN2 and resid 71 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 72 and name HN) (segid AN2 and resid 73 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 72 and name HN) (segid AN2 and resid 73 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 73 and name HN) (segid AN1 and resid 72 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 73 and name HN) (segid AN1 and resid 72 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 73 and name HN) (segid AN1 and resid 74 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 73 and name HN) (segid AN2 and resid 72 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 73 and name HN) (segid AN2 and resid 72 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 73 and name HN) (segid AN2 and resid 74 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 74 and name HN) (segid AN1 and resid 73 and name HA) 2.0 0.5 0.5 assign (segid AN1 and resid 74 and name HN) (segid AN1 and resid 74 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 74 and name HN) (segid AN2 and resid 73 and name HA) 2.0 0.5 0.5 assign (segid AN2 and resid 74 and name HN) (segid AN2 and resid 74 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 75 and name HN) (segid AN1 and resid 74 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 75 and name HN) (segid AN2 and resid 74 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 75 and name HN) (segid AN1 and resid 73 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 75 and name HN) (segid AN1 and resid 76 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 75 and name HN) (segid AN2 and resid 73 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 75 and name HN) (segid AN2 and resid 76 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 76 and name HN) (segid AN1 and resid 75 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 76 and name HN) (segid AN1 and resid 75 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 76 and name HN) (segid AN1 and resid 77 and name HN) 2.6 0.5 0.5 assign (segid AN2 and resid 76 and name HN) (segid AN2 and resid 75 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 76 and name HN) (segid AN2 and resid 75 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 76 and name HN) (segid AN2 and resid 77 and name HN) 2.6 0.5 0.5 assign (segid AN1 and resid 77 and name HN) (segid AN1 and resid 76 and name HD2#) 4.0 0.5 0.5 assign (segid AN1 and resid 77 and name HN) (segid AN1 and resid 76 and name HG) 4.0 0.5 0.5 assign (segid AN1 and resid 77 and name HN) (segid AN1 and resid 78 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 77 and name HN) (segid AN2 and resid 76 and name HD2#) 4.0 0.5 0.5 assign (segid AN2 and resid 77 and name HN) (segid AN2 and resid 76 and name HG) 4.0 0.5 0.5 assign (segid AN2 and resid 77 and name HN) (segid AN2 and resid 78 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 78 and name HN) (segid AN1 and resid 79 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 78 and name HN) (segid AN2 and resid 79 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 78 and name HN) (segid AN1 and resid 77 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 78 and name HN) (segid AN2 and resid 77 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 80 and name HN) (segid AN1 and resid 81 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 80 and name HN) (segid AN2 and resid 81 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 80 and name HD1#) (segid AN1 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN2 and resid 80 and name HD1#) (segid AN2 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN1 and resid 81 and name HN) (segid AN1 and resid 80 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 81 and name HN) (segid AN1 and resid 80 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 81 and name HN) (segid AN1 and resid 82 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 81 and name HN) (segid AN1 and resid 83 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 81 and name HN) (segid AN2 and resid 80 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 81 and name HN) (segid AN2 and resid 80 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 81 and name HN) (segid AN2 and resid 82 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 81 and name HN) (segid AN2 and resid 83 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 81 and name HB#) (segid AN1 and resid 80 and name HB) 4.0 0.5 0.5 assign (segid AN2 and resid 81 and name HB#) (segid AN2 and resid 80 and name HB) 4.0 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 83 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 83 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 81 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 81 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 81 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 81 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 83 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 83 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 82 and name HN) (segid AN1 and resid 80 and name HB) 4.5 0.5 0.5 assign (segid AN2 and resid 82 and name HN) (segid AN2 and resid 80 and name HB) 4.5 0.5 0.5 assign (segid AN1 and resid 82 and name HB#) (segid AN1 and resid 79 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 82 and name HB#) (segid AN2 and resid 79 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 82 and name HB#) (segid AN1 and resid 83 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 82 and name HB#) (segid AN2 and resid 83 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HN) (segid AN1 and resid 82 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 83 and name HN) (segid AN2 and resid 82 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 83 and name HN) (segid AN1 and resid 82 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 83 and name HN) (segid AN2 and resid 82 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 83 and name HN) (segid AN1 and resid 84 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 83 and name HN) (segid AN2 and resid 84 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 83 and name HN) (segid AN1 and resid 82 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 83 and name HN) (segid AN2 and resid 82 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG1#) (segid AN1 and resid 120 and name HD1#) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG1#) (segid AN1 and resid 120 and name HD2#) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG2#) (segid AN1 and resid 120 and name HD1#) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG2#) (segid AN1 and resid 120 and name HD2#) 3.0 0.5 0.5 assign (segid AN1 and resid 83 and name HG1#) (segid AN1 and resid 82 and name HB#) 4.5 1.0 1.0 assign (segid AN2 and resid 83 and name HG1#) (segid AN2 and resid 82 and name HB#) 4.5 1.0 1.0 assign (segid AN1 and resid 83 and name HG2#) (segid AN1 and resid 82 and name HB#) 4.5 1.0 1.0 assign (segid AN2 and resid 83 and name HG2#) (segid AN2 and resid 82 and name HB#) 4.5 1.0 1.0 assign (segid AN1 and resid 83 and name HG#) (segid AN1 and resid 84 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 83 and name HG#) (segid AN2 and resid 84 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 83 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 83 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 83 and name HG1#) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 83 and name HG1#) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 83 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 83 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 82 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 82 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 83 and name HB) 4.0 0.5 0.5 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 83 and name HB) 4.0 0.5 0.5 assign (segid AN1 and resid 84 and name HN) (segid AN1 and resid 85 and name HA) 4.5 1.0 1.0 assign (segid AN2 and resid 84 and name HN) (segid AN2 and resid 85 and name HA) 4.5 1.0 1.0 assign (segid AN1 and resid 85 and name HN) (segid AN1 and resid 84 and name HB#) 2.5 0.5 0.5 assign (segid AN2 and resid 85 and name HN) (segid AN2 and resid 84 and name HB#) 2.5 0.5 0.5 assign (segid AN1 and resid 85 and name HN) (segid AN1 and resid 86 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 85 and name HN) (segid AN2 and resid 86 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 85 and name HN) (segid AN1 and resid 86 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 85 and name HN) (segid AN2 and resid 86 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 85 and name HN) (segid AN1 and resid 85 and name HG2#) 2.0 0.5 0.5 assign (segid AN2 and resid 85 and name HN) (segid AN2 and resid 85 and name HG2#) 2.0 0.5 0.5 assign (segid AN1 and resid 85 and name HG2#) (segid AN1 and resid 86 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 85 and name HG2#) (segid AN2 and resid 86 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 86 and name HN) (segid AN1 and resid 85 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 86 and name HN) (segid AN2 and resid 85 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 86 and name HN) (segid AN1 and resid 85 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 86 and name HN) (segid AN2 and resid 85 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 86 and name HN) (segid AN1 and resid 85 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 86 and name HN) (segid AN2 and resid 85 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 87 and name HN) (segid AN1 and resid 86 and name HB#) 3.5 0.5 0.5 assign (segid AN2 and resid 87 and name HN) (segid AN2 and resid 86 and name HB#) 3.5 0.5 0.5 assign (segid AN1 and resid 87 and name HN) (segid AN1 and resid 86 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 87 and name HN) (segid AN2 and resid 86 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 89 and name HN) (segid AN1 and resid 90 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 89 and name HN) (segid AN2 and resid 90 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 89 and name HN) (segid AN1 and resid 87 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 89 and name HN) (segid AN2 and resid 87 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 89 and name HN) (segid AN1 and resid 89 and name HG#) 2.2 0.5 0.5 assign (segid AN2 and resid 89 and name HN) (segid AN2 and resid 89 and name HG#) 2.2 0.5 0.5 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 89 and name HB#) 3.5 0.5 0.5 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 89 and name HB#) 3.5 0.5 0.5 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 89 and name HD#) 4.0 1.0 1.0 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 89 and name HD#) 4.0 1.0 1.0 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 89 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 89 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 91 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 91 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 90 and name HN) (segid AN1 and resid 90 and name HB#) 2.8 0.5 0.5 assign (segid AN2 and resid 90 and name HN) (segid AN2 and resid 90 and name HB#) 2.8 0.5 0.5 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 120 and name HD2#) 4.0 0.5 0.5 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 120 and name HD2#) 4.0 0.5 0.5 assign (segid AN1 and resid 91 and name HG1#) (segid AN1 and resid 83 and name HG2#) 3.5 1.0 1.0 assign (segid AN2 and resid 91 and name HG1#) (segid AN2 and resid 83 and name HG2#) 3.5 1.0 1.0 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 83 and name HG2#) 3.0 0.5 0.5 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 83 and name HG2#) 3.0 0.5 0.5 assign (segid AN1 and resid 91 and name HG1#) (segid AN1 and resid 83 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 91 and name HG1#) (segid AN2 and resid 83 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 83 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 83 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 91 and name HG1#) (segid AN1 and resid 92 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 91 and name HG1#) (segid AN2 and resid 92 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 92 and name HN) 3.5 1.0 1.0 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 92 and name HN) 3.5 1.0 1.0 assign (segid AN1 and resid 91 and name HG2#) (segid AN1 and resid 92 and name HD1) 4.0 1.5 1.5 assign (segid AN2 and resid 91 and name HG2#) (segid AN2 and resid 92 and name HD1) 4.0 1.5 1.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 93 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 93 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 91 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 91 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 91 and name HG#) 3.0 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 91 and name HG#) 3.0 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 91 and name HB) 3.5 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 91 and name HB) 3.5 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 93 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 93 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 91 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 91 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 92 and name HN) (segid AN1 and resid 120 and name HD2#) 4.5 0.5 0.5 assign (segid AN2 and resid 92 and name HN) (segid AN2 and resid 120 and name HD2#) 4.5 0.5 0.5 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 92 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 92 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 89 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 89 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 90 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 90 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 92 and name HB#) 3.5 1.0 1.0 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 92 and name HB#) 3.5 1.0 1.0 assign (segid AN1 and resid 93 and name HN) (segid AN1 and resid 94 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 93 and name HN) (segid AN2 and resid 94 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 95 and name HN) 2.8 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 95 and name HN) 2.8 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 93 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 93 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 95 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 95 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 91 and name HA) 3.3 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 91 and name HA) 3.3 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 96 and name HB#) 4.5 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 96 and name HB#) 4.5 0.5 0.5 assign (segid AN1 and resid 94 and name HN) (segid AN1 and resid 93 and name HB#) 3.3 0.5 0.5 assign (segid AN2 and resid 94 and name HN) (segid AN2 and resid 93 and name HB#) 3.3 0.5 0.5 assign (segid AN1 and resid 95 and name HN) (segid AN1 and resid 94 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 95 and name HN) (segid AN2 and resid 94 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 95 and name HN) (segid AN1 and resid 94 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 95 and name HN) (segid AN2 and resid 94 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 95 and name HN) (segid AN1 and resid 92 and name HA) 3.7 0.5 0.5 assign (segid AN2 and resid 95 and name HN) (segid AN2 and resid 92 and name HA) 3.7 0.5 0.5 assign (segid AN1 and resid 95 and name HN) (segid AN1 and resid 96 and name HB#) 5.0 0.5 0.5 assign (segid AN2 and resid 95 and name HN) (segid AN2 and resid 96 and name HB#) 5.0 0.5 0.5 assign (segid AN1 and resid 95 and name HG2#) (segid AN1 and resid 92 and name HE2) 4.0 1.0 1.0 assign (segid AN2 and resid 95 and name HG2#) (segid AN2 and resid 92 and name HE2) 4.0 1.0 1.0 assign (segid AN1 and resid 95 and name HG2#) (segid AN1 and resid 96 and name HB#) 4.0 1.0 1.0 assign (segid AN2 and resid 95 and name HG2#) (segid AN2 and resid 96 and name HB#) 4.0 1.0 1.0 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 95 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 95 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 97 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 97 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 98 and name HN) 4.5 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 98 and name HN) 4.5 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 93 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 93 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 95 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 95 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 95 and name HG1#) 3.5 1.0 1.0 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 95 and name HG1#) 3.5 1.0 1.0 assign (segid AN1 and resid 96 and name HN) (segid AN1 and resid 95 and name HG2#) 2.5 1.0 1.0 assign (segid AN2 and resid 96 and name HN) (segid AN2 and resid 95 and name HG2#) 2.5 1.0 1.0 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 113 and name HD#) 3.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 113 and name HD#) 3.0 0.5 0.5 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 97 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 97 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 97 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 97 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 96 and name HB#) (segid AN1 and resid 95 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 96 and name HB#) (segid AN2 and resid 95 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 98 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 98 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 96 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 96 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 96 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 96 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 94 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 94 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 93 and name HA) 3.3 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 93 and name HA) 3.3 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 96 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 96 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 97 and name HN) (segid AN1 and resid 98 and name HB#) 4.5 0.5 0.5 assign (segid AN2 and resid 97 and name HN) (segid AN2 and resid 98 and name HB#) 4.5 0.5 0.5 assign (segid AN1 and resid 97 and name HB#) (segid AN1 and resid 98 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 97 and name HB#) (segid AN2 and resid 98 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 100 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 100 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 99 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 99 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 97 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 97 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 95 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 95 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 96 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 96 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 98 and name HN) (segid AN1 and resid 97 and name HB#) 2.5 0.5 0.5 assign (segid AN2 and resid 98 and name HN) (segid AN2 and resid 97 and name HB#) 2.5 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 98 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 98 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 100 and name HN) 2.7 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 100 and name HN) 2.7 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 98 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 98 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 96 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 96 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 99 and name HN) (segid AN1 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 99 and name HN) (segid AN2 and resid 97 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 100 and name HN) (segid AN1 and resid 101 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 100 and name HN) (segid AN2 and resid 101 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 100 and name HN) (segid AN1 and resid 99 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 100 and name HN) (segid AN2 and resid 99 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 100 and name HN) (segid AN1 and resid 97 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 100 and name HN) (segid AN2 and resid 97 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 100 and name HN) (segid AN1 and resid 100 and name HB#) 2.2 1.0 1.0 assign (segid AN2 and resid 100 and name HN) (segid AN2 and resid 100 and name HB#) 2.2 1.0 1.0 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 102 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 102 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 99 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 99 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 100 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 100 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 97 and name HB#) 4.5 1.0 1.0 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 97 and name HB#) 4.5 1.0 1.0 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 100 and name HB#) 3.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 100 and name HB#) 3.5 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 100 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 100 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 101 and name HN) (segid AN1 and resid 98 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 101 and name HN) (segid AN2 and resid 98 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 101 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 101 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 100 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 100 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 99 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 99 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 100 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 100 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 101 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 101 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 101 and name HB#) 3.4 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 101 and name HB#) 3.4 0.5 0.5 assign (segid AN1 and resid 102 and name HN) (segid AN1 and resid 102 and name HB#) 2.5 0.5 0.5 assign (segid AN2 and resid 102 and name HN) (segid AN2 and resid 102 and name HB#) 2.5 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 104 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 104 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 102 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 102 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 101 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 101 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 102 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 102 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 103 and name HN) (segid AN1 and resid 102 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 103 and name HN) (segid AN2 and resid 102 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 105 and name HN) (segid AN1 and resid 106 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 105 and name HN) (segid AN2 and resid 106 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 106 and name HN) (segid AN1 and resid 105 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 106 and name HN) (segid AN2 and resid 105 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 109 and name HN) (segid AN1 and resid 110 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 109 and name HN) (segid AN2 and resid 110 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 110 and name HN) (segid AN1 and resid 111 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 110 and name HN) (segid AN2 and resid 111 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 110 and name HG1#) (segid AN1 and resid 107 and name HZ#) 3.5 0.5 0.5 assign (segid AN2 and resid 110 and name HG1#) (segid AN2 and resid 107 and name HZ#) 3.5 0.5 0.5 assign (segid AN1 and resid 110 and name HG2#) (segid AN1 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 110 and name HG2#) (segid AN2 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 110 and name HG2#) (segid AN1 and resid 105 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 110 and name HG2#) (segid AN2 and resid 105 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 110 and name HG1#) (segid AN1 and resid 105 and name HE#) 3.5 0.5 0.5 assign (segid AN2 and resid 110 and name HG1#) (segid AN2 and resid 105 and name HE#) 3.5 0.5 0.5 assign (segid AN1 and resid 111 and name HN) (segid AN1 and resid 111 and name HG1#) 4.0 0.5 0.5 assign (segid AN2 and resid 111 and name HN) (segid AN2 and resid 111 and name HG1#) 4.0 0.5 0.5 assign (segid AN1 and resid 111 and name HN) (segid AN1 and resid 111 and name HG2#) 2.5 0.5 0.5 assign (segid AN2 and resid 111 and name HN) (segid AN2 and resid 111 and name HG2#) 2.5 0.5 0.5 assign (segid AN1 and resid 111 and name HN) (segid AN1 and resid 110 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 111 and name HN) (segid AN2 and resid 110 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 111 and name HG1#) 4.0 1.0 1.0 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 111 and name HG1#) 4.0 1.0 1.0 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 111 and name HG2#) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 111 and name HG2#) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 110 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 110 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 110 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 110 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HN) (segid AN1 and resid 114 and name HN) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HN) (segid AN2 and resid 114 and name HN) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HB#) (segid AN1 and resid 115 and name HE#) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HB#) (segid AN2 and resid 115 and name HE#) 4.0 0.5 0.5 assign (segid AN1 and resid 112 and name HB#) (segid AN1 and resid 115 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 112 and name HB#) (segid AN2 and resid 115 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 113 and name HN) (segid AN1 and resid 114 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 113 and name HN) (segid AN2 and resid 114 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 113 and name HN) (segid AN1 and resid 112 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 113 and name HN) (segid AN2 and resid 112 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 113 and name HN) (segid AN1 and resid 112 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 113 and name HN) (segid AN2 and resid 112 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 113 and name HD1#) (segid AN1 and resid 95 and name HG2#) 4.0 1.0 1.0 assign (segid AN1 and resid 113 and name HD#) (segid AN1 and resid 99 and name HE#) 3.5 0.5 0.5 assign (segid AN1 and resid 113 and name HD2#) (segid AN1 and resid 96 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 113 and name HD2#) (segid AN1 and resid 96 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 113 and name HD1#) (segid AN2 and resid 95 and name HG2#) 4.0 1.0 1.0 assign (segid AN2 and resid 113 and name HD#) (segid AN2 and resid 99 and name HE#) 3.5 0.5 0.5 assign (segid AN2 and resid 113 and name HD2#) (segid AN2 and resid 96 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 113 and name HD2#) (segid AN2 and resid 96 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HG) 3.5 1.0 1.0 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HG) 3.5 1.0 1.0 assign (segid AN1 and resid 114 and name HN) (segid AN1 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 114 and name HN) (segid AN2 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 115 and name HN) (segid AN1 and resid 116 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 115 and name HN) (segid AN2 and resid 116 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 115 and name HN) (segid AN1 and resid 114 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 115 and name HN) (segid AN2 and resid 114 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 116 and name HN) (segid AN1 and resid 115 and name HN) 3.5 0.5 0.5 assign (segid AN2 and resid 116 and name HN) (segid AN2 and resid 115 and name HN) 3.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 118 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 118 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 114 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 114 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 116 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 116 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 117 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 117 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 115 and name HA) 4.5 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 115 and name HA) 4.5 0.5 0.5 assign (segid AN1 and resid 117 and name HN) (segid AN1 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN2 and resid 117 and name HN) (segid AN2 and resid 113 and name HD#) 4.0 0.5 0.5 assign (segid AN1 and resid 117 and name HB#) (segid AN1 and resid 121 and name HG#) 4.0 1.0 1.0 assign (segid AN2 and resid 117 and name HB#) (segid AN2 and resid 121 and name HG#) 4.0 1.0 1.0 assign (segid AN1 and resid 117 and name HB#) (segid AN1 and resid 120 and name HD#) 4.0 1.0 1.0 assign (segid AN2 and resid 117 and name HB#) (segid AN2 and resid 120 and name HD#) 4.0 1.0 1.0 assign (segid AN1 and resid 117 and name HB#) (segid AN1 and resid 114 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 117 and name HB#) (segid AN2 and resid 114 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 117 and name HB#) (segid AN1 and resid 114 and name HD#) 3.0 0.5 0.5 assign (segid AN2 and resid 117 and name HB#) (segid AN2 and resid 114 and name HD#) 3.0 0.5 0.5 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 121 and name HG#) 4.5 0.5 0.5 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 121 and name HG#) 4.5 0.5 0.5 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 113 and name HA) 4.5 1.0 1.0 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 113 and name HA) 4.5 1.0 1.0 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 119 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 119 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 117 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 117 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 118 and name HN) (segid AN1 and resid 118 and name HB#) 2.5 0.5 0.5 assign (segid AN2 and resid 118 and name HN) (segid AN2 and resid 118 and name HB#) 2.5 0.5 0.5 assign (segid AN1 and resid 119 and name HN) (segid AN1 and resid 121 and name HG#) 4.0 0.5 0.5 assign (segid AN2 and resid 119 and name HN) (segid AN2 and resid 121 and name HG#) 4.0 0.5 0.5 assign (segid AN1 and resid 119 and name HN) (segid AN1 and resid 118 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 119 and name HN) (segid AN2 and resid 118 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 119 and name HN) (segid AN1 and resid 120 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 119 and name HN) (segid AN2 and resid 120 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 117 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 117 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 119 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 119 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 120 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 120 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 121 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 121 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 120 and name HN) (segid AN1 and resid 119 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HN) (segid AN2 and resid 119 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HD1#) (segid AN1 and resid 83 and name HG2#) 3.5 0.5 0.5 assign (segid AN2 and resid 120 and name HD1#) (segid AN2 and resid 83 and name HG2#) 3.5 0.5 0.5 assign (segid AN1 and resid 120 and name HD2#) (segid AN1 and resid 83 and name HG2#) 3.5 0.5 0.5 assign (segid AN2 and resid 120 and name HD2#) (segid AN2 and resid 83 and name HG2#) 3.5 0.5 0.5 assign (segid AN1 and resid 120 and name HD1#) (segid AN1 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HD1#) (segid AN2 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HD2#) (segid AN1 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HD2#) (segid AN2 and resid 116 and name HE#) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HD2#) (segid AN1 and resid 92 and name HD#) 3.0 0.5 0.5 assign (segid AN2 and resid 120 and name HD2#) (segid AN2 and resid 92 and name HD#) 3.0 0.5 0.5 assign (segid AN1 and resid 120 and name HD2#) (segid AN1 and resid 92 and name HE#) 4.0 0.5 0.5 assign (segid AN2 and resid 120 and name HD2#) (segid AN2 and resid 92 and name HE#) 4.0 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 120 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 120 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 121 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 121 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 122 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 122 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 120 and name HG) 3.5 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 120 and name HG) 3.5 0.5 0.5 assign (segid AN1 and resid 121 and name HN) (segid AN1 and resid 120 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 121 and name HN) (segid AN2 and resid 120 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 121 and name HG1#) (segid AN1 and resid 117 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 121 and name HG1#) (segid AN2 and resid 117 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 121 and name HG1#) (segid AN1 and resid 117 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 121 and name HG1#) (segid AN2 and resid 117 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 121 and name HG2#) (segid AN1 and resid 117 and name HB#) 4.0 0.5 0.5 assign (segid AN2 and resid 121 and name HG2#) (segid AN2 and resid 117 and name HB#) 4.0 0.5 0.5 assign (segid AN1 and resid 121 and name HG2#) (segid AN1 and resid 122 and name HG) 3.5 1.0 1.0 assign (segid AN2 and resid 121 and name HG2#) (segid AN2 and resid 122 and name HG) 3.5 1.0 1.0 assign (segid AN1 and resid 121 and name HG#) (segid AN1 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 121 and name HG#) (segid AN2 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 121 and name HG#) (segid AN1 and resid 118 and name HA) 3.5 1.0 1.0 assign (segid AN2 and resid 121 and name HG#) (segid AN2 and resid 118 and name HA) 3.5 1.0 1.0 assign (segid AN1 and resid 121 and name HG#) (segid AN1 and resid 122 and name HN) 3.5 1.0 1.0 assign (segid AN2 and resid 121 and name HG#) (segid AN2 and resid 122 and name HN) 3.5 1.0 1.0 assign (segid AN1 and resid 122 and name HN) (segid AN1 and resid 121 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 122 and name HN) (segid AN2 and resid 121 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 122 and name HN) (segid AN1 and resid 121 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 122 and name HN) (segid AN2 and resid 121 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 122 and name HN) (segid AN1 and resid 122 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 122 and name HN) (segid AN2 and resid 122 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 122 and name HD1#) (segid AN1 and resid 118 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 122 and name HD1#) (segid AN2 and resid 118 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 122 and name HD#) (segid AN1 and resid 119 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 122 and name HD#) (segid AN2 and resid 119 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 122 and name HD#) (segid AN1 and resid 122 and name HB#) 2.1 0.5 0.5 assign (segid AN2 and resid 122 and name HD#) (segid AN2 and resid 122 and name HB#) 2.1 0.5 0.5 assign (segid AN1 and resid 123 and name HN) (segid AN1 and resid 120 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 123 and name HN) (segid AN2 and resid 120 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 123 and name HN) (segid AN1 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 123 and name HN) (segid AN2 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 123 and name HN) (segid AN1 and resid 123 and name HA) 2.5 0.5 0.5 assign (segid AN2 and resid 123 and name HN) (segid AN2 and resid 123 and name HA) 2.5 0.5 0.5 assign (segid AN1 and resid 123 and name HN) (segid AN1 and resid 124 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 123 and name HN) (segid AN2 and resid 124 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 123 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 123 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 120 and name HA) 3.6 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 120 and name HA) 3.6 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 121 and name HA) 3.3 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 121 and name HA) 3.3 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 123 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 123 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 124 and name HN) (segid AN1 and resid 123 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 124 and name HN) (segid AN2 and resid 123 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 124 and name HB#) (segid AN1 and resid 123 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 124 and name HB#) (segid AN2 and resid 123 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 124 and name HB#) (segid AN1 and resid 121 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 124 and name HB#) (segid AN2 and resid 121 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 125 and name HN) (segid AN1 and resid 126 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 125 and name HN) (segid AN2 and resid 126 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 125 and name HN) (segid AN1 and resid 124 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 125 and name HN) (segid AN2 and resid 124 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 125 and name HN) (segid AN1 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 125 and name HN) (segid AN2 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 125 and name HN) (segid AN1 and resid 126 and name HA) 4.0 1.0 1.0 assign (segid AN2 and resid 125 and name HN) (segid AN2 and resid 126 and name HA) 4.0 1.0 1.0 assign (segid AN1 and resid 125 and name HD2#) (segid AN1 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 125 and name HD2#) (segid AN2 and resid 122 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 125 and name HD1#) (segid AN1 and resid 122 and name HA) 4.0 0.5 0.5 assign (segid AN2 and resid 125 and name HD1#) (segid AN2 and resid 122 and name HA) 4.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 127 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 127 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 125 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 125 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 125 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 125 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 123 and name HA) 3.5 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 123 and name HA) 3.5 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 125 and name HG) 3.5 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 125 and name HG) 3.5 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 125 and name HB#) 3.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 125 and name HB#) 3.0 0.5 0.5 assign (segid AN1 and resid 126 and name HN) (segid AN1 and resid 124 and name HB#) 5.0 0.5 0.5 assign (segid AN2 and resid 126 and name HN) (segid AN2 and resid 124 and name HB#) 5.0 0.5 0.5 assign (segid AN1 and resid 127 and name HN) (segid AN1 and resid 126 and name HA) 3.0 0.5 0.5 assign (segid AN2 and resid 127 and name HN) (segid AN2 and resid 126 and name HA) 3.0 0.5 0.5 assign (segid AN1 and resid 127 and name HN) (segid AN1 and resid 128 and name HN) 2.5 0.5 0.5 assign (segid AN2 and resid 127 and name HN) (segid AN2 and resid 128 and name HN) 2.5 0.5 0.5 assign (segid AN1 and resid 127 and name HN) (segid AN1 and resid 126 and name HN) 3.0 0.5 0.5 assign (segid AN2 and resid 127 and name HN) (segid AN2 and resid 126 and name HN) 3.0 0.5 0.5 assign (segid AN1 and resid 127 and name HN) (segid AN1 and resid 125 and name HD1#) 4.5 1.0 1.0 assign (segid AN2 and resid 127 and name HN) (segid AN2 and resid 125 and name HD1#) 4.5 1.0 1.0 assign (segid AN1 and resid 127 and name HG2#) (segid AN1 and resid 128 and name HN) 3.0 1.0 1.0 assign (segid AN2 and resid 127 and name HG2#) (segid AN2 and resid 128 and name HN) 3.0 1.0 1.0 assign (segid AN1 and resid 128 and name HN) (segid AN1 and resid 127 and name HB) 4.0 0.5 0.5 assign (segid AN2 and resid 128 and name HN) (segid AN2 and resid 127 and name HB) 4.0 0.5 0.5
Contact the webmaster for help, if required. Saturday, May 18, 2024 7:01:51 AM GMT (wattos1)